问答中心分类: BuilderGEM模型跑出来没有储量,同样的操作换一套PVT导进来就可以计算出来,这是为什么呢
0
xiaozheng asked 1年 ago

模型跑出来的结果

2 Answers
0
wuxiaoyun 管理员 answered 10月 ago

没有储量的意思是没有油吗?如果换一套PVT,就可以输出的话,可能问题出现在PVT。
可以在REsults中查看初始饱和度场的分布,或者WinProp计算一下当前流体在储层条件下的相态。

0
xiaozheng answered 9月 ago

请问我网格个数12*40*1,尺寸2.5cm*2.5cm*1cm,一共建立了三口水平井,一口注入井,一口注水井,一口生产井,设置的各参数也在合理范围,为什么注气井的井底流压总是不收敛呢?如果把模型长宽高都放大100倍,单个网格尺寸为25m*25m*1m就可以收敛了,请问有什么办法解决小模型呢?谢谢
= WARNING (from subroutine: W1BRWI) ======================
Well number 1 (‘inj-gas’).
Iteration for pwfk fails to converge.
==============================================================================

===================== WARNING (from subroutine: W1BRWI) ======================
Well number 1 (‘inj-gas’).
Iteration for pwfk fails to converge.
==============================================================================

===================== WARNING (from subroutine: W1BRWI) ======================
Well number 1 (‘inj-gas’).
Iteration for pwfk fails to converge.
==============================================================================
— Repeat time step: program failed to converge
6 6.6e-5 9 1.2e-3 2023.04.01 4,32 1.047 5,8 -49e-4(o) 4,32 -21e-3(11) .1439 6 7.6 0
===================== WARNING (from subroutine: W1BRWI) ======================
Well number 1 (‘inj-gas’).
Iteration for pwfk fails to converge.
==============================================================================

===================== WARNING (from subroutine: W1BRWI) ======================
Well number 1 (‘inj-gas’).
Iteration for pwfk fails to converge.
==============================================================================

===================== WARNING (from subroutine: W1BRWI) ======================
Well number 1 (‘inj-gas’).
Iteration for pwfk fails to converge.
=============================================================================