问答中心分类: Builder模型运行终止,显示water moles disappear和unusual pressure是为什么呢
0
123 asked 3月 ago

模型运行常常出现以下问题导致终止,但是有时候又没问题,一模一样的参数设置的情况下有些会出现以下问题请问应该如何解决呢,看起来似乎是某个网格的问题,请问具体应该如何调整呢。
 
— Repeat time step: water moles disappear in block: 10356 ( 6,8,5 )
— Repeat time step: water moles disappear in block: 10356 ( 6,8,5 )
— Repeat time step: water moles disappear in block: 10356 ( 6,8,5 )
— Repeat time step: water moles disappear in block: 10356 ( 6,8,5 )
— Repeat time step: water moles disappear in block: 10356 ( 6,8,5 )
— Repeat time step: water moles disappear in block: 10356 ( 6,8,5 )
— Repeat time step: water moles disappear in block: 10356 ( 6,8,5 )
— Repeat time step: water moles disappear in block: 10356 ( 6,8,5 )
— Repeat time step: water moles disappear in block: 10356 ( 6,8,5 )
— Repeat time step: water moles disappear in block: 10356 ( 6,8,5 )
— Repeat time step: unusual pressure in block: 10306 ( 6,7,5 )
— Repeat time step: unusual pressure in block: 10356 ( 6,8,5 )
— Repeat time step: unusual pressure in block: 10356 ( 6,8,5 )
— Repeat time step: unusual pressure in block: 10356 ( 6,8,5 )
— Repeat time step: unusual pressure in block: 10356 ( 6,8,5 )
— Repeat time step: unusual pressure in block: 10356 ( 6,8,5 )
— Repeat time step: unusual pressure in block: 10356 ( 6,8,5 )
— Repeat time step: unusual pressure in block: 10356 ( 6,8,5 )
— Repeat time step: unusual pressure in block: 10356 ( 6,8,5 )

1 Answers
0
wangjianguo 管理员 answered 2月 ago

您好!
该提示信息表明有些网格的水相消失,可能是变成了气相?
有些网格的压力不合理。
检查一下这些网格,看看有没有异常。

123 replied 2月 ago

您好,我在进行水气交替的模拟,每个网格的压力都是一样的,请问具体应该如何检查如何解决呢